citation |
- title:
- Ground based in situ observations of online_crds at Angus (GB0056R)
- dates:
- fileIdentifier:
- EBAS/GB0056R.20120407000000.20151222151400.online_crds..air.3y.1h.GB05L_Piacrro_CRDS_G2301_TTA.GB05L_ACRG_DECC_PICARRO_222.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "GB0056R.20120407000000.20151222151400.online_crds..air.3y.1h.GB05L_Piacrro_CRDS_G2301_TTA.GB05L_ACRG_DECC_PICARRO_222.lev2.nc",
"File creation": "20190514043051",
"Startdate": "20120407000000",
"Revision date": "20151222151400",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1s",
"Station code": "GB0056R",
"Platform code": "GB0056S",
"Station name": "Angus",
"Station latitude": "56.5551",
"Station longitude": "-2.9858",
"Station altitude": "400.0 m",
"Measurement height": "222.0 m",
"Regime": "IMG",
"Matrix": "air",
"Laboratory code": "GB05L",
"Instrument type": "online_crds",
"Instrument name": "Piacrro_CRDS_G2301_TTA",
"Instrument manufacturer": "Picarro",
"Instrument model": "G2301",
"Instrument serial number": "2316",
"Method ref": "GB05L_ACRG_DECC_PICARRO_222",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood, 222 m, stainless steel, flow ~20 l/min",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Organization": "GB05L, \"ACRG, University of Bristol, School of Chemistry, Cantocks Close, BS8 1TS, Bristol, United Kingdom\", UNIVBRIS, , \"Cantocks Close,, BS8 1TS, Bristol, United Kingdom\", , , , ",
"Frameworks": "GAW-WDCGG-node UK_DECC",
"Originator": "Grant, Aoife, , , , , , , , , ",
"Submitter": "Manning, Alistair, am12721@bristol.ac.uk, University of Bristol, Atmospheric Chem, , Cantocks Close, , BS8 1TS, Bristol, United Kingdom",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "No SOP currently available, target run every 20 hours for 20 mins, calibration suite run every 28 days."
}
|