citation |
- title:
- Ground based in situ observations of online_crds at Bilsdale (GB0058R)
- dates:
- fileIdentifier:
- EBAS/GB0058R.20140130110000.20180921131200.online_crds..air.5y.1h.GB05L_Picarro_CRDS_G2401_BSD.GB05L_ACRG_DECC_PICARRO_108.lev1.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "GB0058R.20140130110000.20180921131200.online_crds..air.5y.1h.GB05L_Picarro_CRDS_G2401_BSD.GB05L_ACRG_DECC_PICARRO_108.lev1.nc",
"File creation": "20190514043242",
"Startdate": "20140130110000",
"Revision date": "20180921131200",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "1",
"Period code": "5y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1s",
"Station code": "GB0058R",
"Platform code": "GB0058S",
"Station name": "Bilsdale",
"Station latitude": "54.35832",
"Station longitude": "-1.15055",
"Station altitude": "380.0 m",
"Measurement height": "108.0 m",
"Regime": "IMG",
"Matrix": "air",
"Laboratory code": "GB05L",
"Instrument type": "online_crds",
"Instrument name": "Picarro_CRDS_G2401_BSD",
"Instrument manufacturer": "Picarro",
"Instrument model": "G2401",
"Instrument serial number": "2179",
"Method ref": "GB05L_ACRG_DECC_PICARRO_108",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood, 108 m, stainless steel, flow ~20 l/min",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Organization": "GB05L, \"ACRG, University of Bristol, School of Chemistry, Cantocks Close, BS8 1TS, Bristol, United Kingdom\", UNIVBRIS, , \"Cantocks Close,, BS8 1TS, Bristol, United Kingdom\", , , , ",
"Frameworks": "GAW-WDCGG-node UK_DECC",
"Originator": "Stavert, Ann, , University of Bristol, ACRG, Atmospheric Chemistry Research Group, Cantocks Close, , BS8 1TS, Bristol, United Kingdom",
"Submitter": "Stanley, Kieran, k.m.stanley@bristol.ac.uk, University of Bristol, ACRG, Atmospheric Chemistry Research Group, Cantocks Close, , BS8 1TS, Bristol, United Kingdom",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "No SOP currently available, instrument specific H2O correction coefficients used to derive dry mole fractions, target run every 20 hours for 20 mins, calibration suite ru"
}
|