citation |
- title:
- Ground based in situ observations of total_carbon at Finokalia (GR0002R) using low_vol_sampler
- dates:
- fileIdentifier:
- EBAS/GR0002R.20151231220000.20170719000000.low_vol_sampler.total_carbon.pm10.1y.1d.GR02L_PM10_carbon.GR02L_GR002_sunset.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "GR0002R.20151231220000.20170719000000.low_vol_sampler.total_carbon.pm10.1y.1d.GR02L_PM10_carbon.GR02L_GR002_sunset.lev2.nc",
"File creation": "20190514044254",
"Startdate": "20151231220000",
"Revision date": "20170719000000",
"Version": "1",
"Version description": "initial revision",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "GR0002R",
"Platform code": "GR0002S",
"Station name": "Finokalia",
"Station latitude": "35.316667",
"Station longitude": "25.666667",
"Station altitude": "250.0 m",
"Measurement latitude": "35.338",
"Measurement longitude": "25.669",
"Measurement altitude": "250.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Component": "total_carbon",
"Unit": "ug C/m3",
"Matrix": "pm10",
"Laboratory code": "GR02L",
"Instrument type": "low_vol_sampler",
"Instrument name": "PM10_carbon",
"Instrument manufacturer": "Leckel",
"Instrument model": "SEQ47/50",
"Instrument serial number": "10/0090",
"Analytical laboratory code": "GR02L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument name": "GR002_sunset",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Analytical instrument model": "OCEC Lab Instrument Model 5",
"Analytical instrument serial number": "170",
"Method ref": "GR02L_GR002_sunset",
"Standard method": "TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet",
"Flow rate": "38.5 l/min",
"Filter face velocity": "56.58 cm/s",
"Exposed filter area": "11.34 cm2",
"Filter description": "Pall Tissuquartz 2500 QAT-UP 47mm",
"Medium": "Quartz",
"Filter prefiring": "Not prefired",
"Filter conditioning": "None",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Artifact correction": "None",
"Charring correction": "By laser transmission",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter was maintained in a refrigerator at 25 degrees",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"QA1 measure ID": "EMEP-ACTRIS-ECOC-2015",
"QA1 date": "20151022",
"QA1 document URL": "http://www.nilu.no/projects/ccc/qameasure/ecoc_2015.pdf",
"Organization": "GR02L, Ministry of Environment, , , , , , , ",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Kouvarakis, Giorgos, , , , , , , , , ",
"Submitter": "Kouvarakis, Giorgos, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|