citation |
- title:
- Ground based in situ observations of nephelometer at DEM_Athens (GR0100B)
- dates:
- fileIdentifier:
- EBAS/GR0100B.20140101000000.20151029000000.nephelometer..pm10.1y.1h.GR05L_Ecotech_Aurora3000_DemStation_pm10.GR05L_NephAurora.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "GR0100B.20140101000000.20151029000000.nephelometer..pm10.1y.1h.GR05L_Ecotech_Aurora3000_DemStation_pm10.GR05L_NephAurora.lev2.nc",
"File creation": "20190514044645",
"Startdate": "20140101000000",
"Revision date": "20151029000000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "GR0100B",
"Platform code": "GR0100S",
"Station name": "DEM_Athens",
"Station WDCA-ID": "GAWAGR__DEM",
"Station GAW-ID": "DEM",
"Station GAW-Name": "Demokritos Athens",
"Station land use": "Forest",
"Station setting": "Urban and center city",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "37.9949989319",
"Station longitude": "23.8159999847",
"Station altitude": "270.0 m",
"Measurement latitude": "37.995",
"Measurement longitude": "23.816",
"Measurement altitude": "270.0 m",
"Measurement height": "10.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "GR05L",
"Instrument type": "nephelometer",
"Instrument name": "Ecotech_Aurora3000_DemStation_pm10",
"Instrument manufacturer": "Ecotech",
"Instrument model": "Aurora3000",
"Instrument serial number": "07-1774",
"Method ref": "GR05L_NephAurora",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=Müller2011",
"Inlet type": "Impactor--direct",
"Inlet description": "pm10 impactor for a nominal flow of 8 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "The sample is dried in a nafion dryer by counterflow of filtered, dry air and measured at sample inlet",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.3 1/Mm",
"Detection limit expl.": "T. Muller et al, Atmos. Meas. Tech., 4, 1291-1303, 2011, no detection limit flag used",
"Measurement uncertainty": "2.5 %",
"Measurement uncertainty expl.": "average value taken from Calibration uncertainty, Ecotech manual 2009 and T. Muller et al, Atmos. Meas. Tech., 4, 1291-1303, 2011",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "GR05L, National Centre of Scientific Research, , , \"Demokritos, Athens, Greece\", , , , ",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Vratolis, Sterios, , , , , , , , , ",
"Submitter": "Vratolis, Sterios, , , , , , , , , ",
"Comment": "Standard values used for truncation correction, table 3A, T. Muller et al, (Atmos. Meas. Tech., 4, 1291-1303, 2011)"
}
|