citation |
- title:
- Ground based in situ observations of pm10_mass at Puntijarka (HR0002R) using low_vol_sampler
- dates:
- fileIdentifier:
- EBAS/HR0002R.20180101000000.20201111105516.low_vol_sampler.pm10_mass.pm10.1y.1d.HR01L_PTLWS.HR01L_pm10_lvs.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "HR0002R.20180101000000.20201111105516.low_vol_sampler.pm10_mass.pm10.1y.1d.HR01L_PTLWS.HR01L_pm10_lvs.lev2.nc",
"File creation": "20201112214224",
"Startdate": "20180101000000",
"Revision date": "20201111105516",
"Version": "1",
"Version description": "initial revision",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "HR0002R",
"Platform code": "HR0002S",
"Station name": "Puntijarka",
"Station latitude": "45.9",
"Station longitude": "15.966667",
"Station altitude": "988.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Component": "pm10_mass",
"Unit": "ug/m3",
"Matrix": "pm10",
"Laboratory code": "HR01L",
"Instrument type": "low_vol_sampler",
"Instrument name": "PTLWS",
"Instrument manufacturer": "Derenda",
"Instrument model": "PNS 16T",
"Instrument serial number": "129",
"Method ref": "HR01L_pm10_lvs",
"Standard method": "SOP=EN12341:2014",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet,deliverd with sampler,flow 2.3m3/h",
"Medium": "Teflon",
"Sample preparation": "Temperature and humidity equilibration",
"Blank correction": "Not blank corrected",
"Humidity/temperature control": "Temperature conditioning at ambient",
"Humidity/temperature control description": "Temperature conditioning at ambient temperature ± 5°C for ambient temperature greater than 20°C",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit": "1.0 ug/m3",
"Detection limit expl.": "limit of detection of the standard measurement method expressed as its uncertainty",
"Measurement uncertainty": "6.5 %",
"Measurement uncertainty expl.": "for maximum daily limit value L=50 ug/m3, k=2 and 95 % level of confidence as described in EN123412014",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if with in detection limit,flagged with 780",
"Organization": "HR01L, Meteorological and Hydrological Service of Croatia, , Environment Division, \"Gric 3, P.O.Box 254\", , 10000, Zagreb, Croatia",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Herjavic, Glenda, herjavic@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia",
"Submitter": "Herjavic, Glenda, herjavic@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|