citation |
- title:
- Ground based in situ observations of low_vol_sampler at Puntijarka (HR0002R)
- dates:
- fileIdentifier:
- EBAS/HR0002R.20180101000000.20211109140154.low_vol_sampler..aerosol.3y.1d.HR01L_PTLWS.HR01L_DHMZ_GCMS.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "HR0002R.20180101000000.20211109140154.low_vol_sampler..aerosol.3y.1d.HR01L_PTLWS.HR01L_DHMZ_GCMS.lev2.nc",
"File creation": "2021-11-09T17:59:41.451827 UTC",
"Export state": "2021-11-09T17:25:03.543000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20180101000000",
"Revision date": "20211109140154",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "3y",
"Resolution code": "1d",
"Sample duration": "1d",
"Station code": "HR0002R",
"Platform code": "HR0002S",
"Station name": "Puntijarka",
"Station latitude": "45.9",
"Station longitude": "15.966667",
"Station altitude": "988.0 m",
"Regime": "IMG",
"Unit": "ng/m3",
"Matrix": "aerosol",
"Laboratory code": "HR01L",
"Instrument type": "low_vol_sampler",
"Instrument name": "PTLWS",
"Instrument manufacturer": "Derenda",
"Instrument model": "PNS 16T",
"Instrument serial number": "129",
"Analytical laboratory code": "HR01L",
"Analytical measurement technique": "GC-MS",
"Analytical instrument name": "DHMZ_GCMS",
"Method ref": "HR01L_DHMZ_GCMS",
"Standard method": "SOP=EMEP_manual_v2014",
"Inlet type": "Impactor--direct",
"Inlet description": "Hat or hood",
"Flow rate": "38.3333333333 l/min",
"Filter description": "Fluoropore FSLW04700",
"Medium": "Teflon",
"Sample preparation": "Organic extraction",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "None",
"Zero/negative values code": "Zero possible",
"Organization": "HR01L, Meteorological and Hydrological Service of Croatia, , Environment Division, \"Gric 3, P.O.Box 254\", , 10000, Zagreb, Croatia",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Kuna, Ksenija, kuna@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia",
"Submitter": "Kuna, Ksenija, kuna@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia"
}
|