Ground based in situ observations of low_vol_sampler at Puntijarka (HR0002R)

Abstract:
Ground based in situ observations of low_vol_sampler at Puntijarka (HR0002R). These measurements are gathered as a part of the following projects EMEP and they are stored in the EBAS database (http://ebas.nilu.no/). Parameters measured are: benz_a_anthracene in pm10 (mass_concentration_of_benz_a_anthracene_in_pm10_in_air), benzo_a_pyrene in pm10 (mass_concentration_of_benzo_a_pyrene_in_pm10_in_air), benzo_bjk_fluoranthenes in pm10 (mass_concentration_of_benzo_bjk_fluoranthenes_in_pm10_in_air), benzo_ghi_perylene in pm10 (mass_concentration_of_benzo_ghi_perylene_in_pm10_in_air), chrysene in pm10 (mass_concentration_of_chrysene_in_pm10_in_air), dibenzo_ah_anthracene in pm10 (mass_concentration_of_dibenzo_ah_anthracene_in_pm10_in_air), inden_123cd_pyrene in pm10 (mass_concentration_of_inden_123cd_pyrene_in_pm10_in_air)

Download plain xml file

To get the data: go to WIS-Portal

Metadata Information

General

General information section
AttributeValue
fileIdentifier/identifierebas:HR0002R.20210101000000.20220101000000.low_vol_sampler..pm10.1y.1d.HR01L_PTLWS.HR01L_DHMZ_GCMS.lev2.nc
languageeng
characterSetUTF8
hierarchyLeveldataset
hierarchyLevelName
    contactsee section contact (role: pointOfContact)
    dateStamp 2022-02-17
    metadataStandardNameISO 19115-2 Geographic Information - Metadata Part 2 Extensions for imagery and gridded data
    metadataStandardVersionISO 19115-2:2009(E)
    referenceSystemInfo
    metadataExtensionInfo

    identificationInfo

    Identification information section
    AttributeValue
    citation
    • title:
      • Ground based in situ observations of low_vol_sampler at Puntijarka (HR0002R)
    • dates:
      • creation:
      • revision:
    • fileIdentifier:
      • EBAS/HR0002R.20210101000000.20220101000000.low_vol_sampler..pm10.1y.1d.HR01L_PTLWS.HR01L_DHMZ_GCMS.lev2.nc
        (CodeSpace: )
    • citedResponsibleParty:
      • see section contact (role: distributor)
    • presentationForm:
    • otherCitationDetails:
      • { "Data definition": "EBAS_1.1", "Set type code": "TU", "Timezone": "UTC", "File name": "HR0002R.20210101000000.20220101000000.low_vol_sampler..pm10.1y.1d.HR01L_PTLWS.HR01L_DHMZ_GCMS.lev2.nc", "File creation": "2022-02-17T17:27:10.138015 UTC", "Export state": "2022-02-17T17:25:03.143000 UTC", "Export filter": "exclude-900,exclude-invalid", "Startdate": "20210101000000", "Revision date": "20220101000000", "Version": "1", "Version description": "initial revision, manually inspected", "Statistics": "arithmetic mean", "Data level": "2", "Period code": "1y", "Resolution code": "1d", "Sample duration": "1d", "Station code": "HR0002R", "Platform code": "HR0002S", "Station name": "Puntijarka", "Station latitude": "45.9", "Station longitude": "15.966667", "Station altitude": "988.0 m", "Regime": "IMG", "Unit": "ng/m3", "Matrix": "pm10", "Laboratory code": "HR01L", "Instrument type": "low_vol_sampler", "Instrument name": "PTLWS", "Instrument manufacturer": "Derenda", "Instrument model": "PNS 16T", "Analytical laboratory code": "HR01L", "Analytical measurement technique": "GC-MS", "Analytical instrument name": "DHMZ_GCMS", "Method ref": "HR01L_DHMZ_GCMS", "Standard method": "SOP=EMEP_manual_v2014", "Inlet type": "Impactor--direct", "Inlet description": "Hat or hood", "Flow rate": "38.3333333333 l/min", "Filter description": "Fluoropore FSLW04700", "Medium": "Teflon", "Sample preparation": "Organic extraction", "Blank correction": "Blank corrected", "Humidity/temperature control": "None", "Zero/negative values code": "Zero possible", "Organization": "HR01L, Meteorological and Hydrological Service of Croatia, , Environment Division, \"Gric 3, P.O.Box 254\", , 10000, Zagreb, Croatia", "Framework acronym": "EMEP", "Framework name": "European Monitoring and Evaluation Programme", "Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.", "Framework contact name": "Kjetil Tørseth", "Framework contact email": "kt@nilu.no", "Originator": "Kuna, Ksenija, kuna@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia", "Submitter": "Kuna, Ksenija, kuna@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia" }
    abstract see above
    status
    purpose
    pointOfContactsee section contact (role: originator)
    graphicOverview
    resourceMaintenance
    • maintenanceAndUpdateFrequency:
    • updateScope:
    • maintenanceNote:
    descriptiveKeywords:
    • theme:
      • mass_concentration_of_benzo_bjk_fluoranthenes_in_pm10_in_air
      • pm10
      • inden_123cd_pyrene
      • mass_concentration_of_chrysene_in_pm10_in_air
      • HR0002R
      • benzo_a_pyrene
      • EMEP
      • mass_concentration_of_dibenzo_ah_anthracene_in_pm10_in_air
      • benzo_bjk_fluoranthenes
      • benz_a_anthracene
      • benzo_ghi_perylene
      • dibenzo_ah_anthracene
      • mass_concentration_of_benz_a_anthracene_in_pm10_in_air
      • mass_concentration_of_inden_123cd_pyrene_in_pm10_in_air
      • mass_concentration_of_benzo_ghi_perylene_in_pm10_in_air
      • Puntijarka
      • mass_concentration_of_benzo_a_pyrene_in_pm10_in_air
      • chrysene
    • project:
      • EMEP
    • dataCenter:
      • NILU - Norwegian Institute for Air Research, ATMOS, EBAS
    • theme:
      • mass_concentration_of_benzo_a_pyrene_in_pm10_in_air
      • mass_concentration_of_inden_123cd_pyrene_in_pm10_in_air
      • status_flag
      • status_flag
      • status_flag
      • status_flag
      • mass_concentration_of_benzo_bjk_fluoranthenes_in_pm10_in_air
      • status_flag
      • mass_concentration_of_chrysene_in_pm10_in_air
      • status_flag
      • mass_concentration_of_benzo_ghi_perylene_in_pm10_in_air
      • mass_concentration_of_dibenzo_ah_anthracene_in_pm10_in_air
      • status_flag
      • mass_concentration_of_benz_a_anthracene_in_pm10_in_air
      • time
      • time
    resourceConstraints
    • MD_Constraints:
      • useLimitation:
    • MD_LegalConstraints:
      • accessConstraints:
      • useConstraints:
      • otherConstraints:
    language
    characterSet
    topicCategoryclimatologyMeteorologyAtmosphere
    extentboundingExtent
    • description:
    • geographicElement:
      • westBoundLongitude: 15.966667
      • eastBoundLongitude: 15.966667
      • southBoundLatitude: 45.9
      • northBoundLatitude: 45.9
    • temporalElement:
      • beginPosition:
      • endPosition: (indeterminatePosition = )

    Contact

    Role: pointOfContact

    Contact information section
    AttributeValue
    individualNameKsenija Kuna
    organisationNameHR01L, Meteorological and Hydrological Service of Croatia, Environment Division, Gric 3, P.O.Box 254, 10000, Zagreb, Croatia
    contactInfo

    Role: distributor

    AttributeValue
    individualName
    organisationName NILU - Norwegian Institute for Air Research, ATMOS, EBAS
    positionName
    contactInfo

    Role: originator

    Originator information section
    AttributeValue
    organisationNameHR01L, Meteorological and Hydrological Service of Croatia, Environment Division, Gric 3, P.O.Box 254, 10000, Zagreb, Croatia
    contactInfo

    contentInfo

    Content information section
    AttributeValue
    CoverageDescription:
    • attributeDescription
    • contentType

    distributionInfo

    Distribution information section
    AttributeValue
    distributionFormat
    • name:
    • version:
      • (gco:nilReason=)
    • specification:
    transferOptions (onLine)
    • linkage/ URL:
    • protocol:
    • name:
    • description:

    dataQualityInfo

    Data Quality information section
    AttributeValue
    scopedataset
    report
    • title:
    • date ():
    • explanation:
    • pass:
    lineage
    • statement:
      • None
    • processStep: