citation |
- title:
- Ground based in situ observations of precip at Zavizan (HR0004R) using bulk_sampler
- dates:
- fileIdentifier:
- EBAS/HR0004R.20130101000000.20211109140902...precip.5y.1d..HR01L_IC84-122.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "HR0004R.20130101000000.20211109140902...precip.5y.1d..HR01L_IC84-122.lev2.nc",
"File creation": "2022-05-06T16:40:48.649804 UTC",
"Export state": "2022-05-06T16:25:02.673000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20130101000000",
"Revision date": "20211109140902",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "5y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "HR0004R",
"Platform code": "HR0004S",
"Station name": "Zavizan",
"Station latitude": "44.816667",
"Station longitude": "14.983333",
"Station altitude": "1594.0 m",
"Measurement height": "1.5 m",
"Regime": "IMG",
"Matrix": "precip",
"Laboratory code": "HR01L",
"Analytical laboratory code": "HR01L",
"Analytical measurement technique": "IC",
"Analytical instrument name": "IC84-122",
"Analytical instrument manufacturer": "Thermo Scientific",
"Analytical instrument model": "ICS-2100",
"Analytical instrument serial number": "11030205-13030345",
"Method ref": "HR01L_IC84-122",
"Standard method": "SOP=EMEP_manual_v2014",
"Blank correction": "Not blank corrected",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of laboratory blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 147",
"Organization": "HR01L, Meteorological and Hydrological Service of Croatia, , Environment Division, \"Gric 3, P.O.Box 254\", , 10000, Zagreb, Croatia",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Igrec, Ivona, igrec@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia",
"Submitter": "Bregni, Ivana, bregni@cirus.dhz.hr, Croatian Meteorological and Hydrological Service, DHMZ, Chemical Laboratory Department, Gric 3, , 10000, Zagreb, Croatia",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|