citation |
- title:
- Ground based in situ observations of ozone at Bukit Kototabang (ID1013R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/ID1013R.20070101000000.20190425132054.uv_abs.ozone.air.6y.1h.ID04L_TEI49C_no58547318.ID04L_uv_abs.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "ID1013R.20070101000000.20190425132054.uv_abs.ozone.air.6y.1h.ID04L_TEI49C_no58547318.ID04L_uv_abs.lev2.nc",
"File creation": "20190514050134",
"Startdate": "20070101000000",
"Revision date": "20190425132054",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "6y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "ID1013R",
"Platform code": "ID1013S",
"Station name": "Bukit Kototabang",
"Station WDCA-ID": "GAWAID__BKT",
"Station GAW-ID": "BKT",
"Station GAW-Name": "Bukit Kototabang",
"Station land use": "Forest",
"Station setting": "Mountain",
"Station GAW type": "G",
"Station WMO region": "5",
"Station latitude": "-0.20194",
"Station longitude": "100.3181",
"Station altitude": "864.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "ID04L",
"Instrument type": "uv_abs",
"Instrument name": "TEI49C_no58547318",
"Instrument manufacturer": "Thermo",
"Instrument model": "49C",
"Instrument serial number": "58547318",
"Method ref": "ID04L_uv_abs",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "inlet approx. 2.5 m above the station and 10 m above the ground",
"Inlet tube material": "Teflon",
"Maintenance description": "inlet filter (47 mm teflon filter (5 micron)) changed every year",
"Flow rate": "1.0 l/min",
"Humidity/temperature control": "Other (see metadata)",
"Humidity/temperature control description": "A cold trap (5 deg C) is used to reduce the humidity in the sample and to avoid downstream condensation. Lab temp is set to 25 degC.",
"Measurement uncertainty expl.": "includes statistical uncertainty of individual sample and calibration uncertainty",
"Absorption cross section": "1.1476e-17 cm2",
"Organization": "ID04L, Badan Meteorologi Klimatologi dan Geofisika, BMKG, Global Atmosphere Watch Bukit Kototabang, P.O. Box 11, , 26100, Bukittinggi - West Sumatra, Indonesia",
"Frameworks": "GAW-WDCRG",
"Originator": "Mehdi, Reza, reza_elka@yahoo.com, Badan Meteorologi Klimatologi dan Geofisika, BMKG, Stasiun Pemantau Atmosfer Global Bukit Kototabang, Jl Raya Bukittinggi-Medan Km 17 Palupuh, PO BOX 11, 26100, Bukittinggi, Indonesia",
"Submitter": "Steinbacher, Martin, martin.steinbacher@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|