citation |
- title:
- Ground based in situ observations of aerosol_absorption_coefficient at Ispra (IT0004R) using filter_absorption_photometer
- dates:
- fileIdentifier:
- EBAS/IT0004R.20160101000000.20200609081113.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.1y.1h.IT04L_MAAP-5012_B.IT04L_MAAP.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "IT0004R.20160101000000.20200609081113.filter_absorption_photometer.aerosol_absorption_coefficient.pm10.1y.1h.IT04L_MAAP-5012_B.IT04L_MAAP.lev2.nc",
"File creation": "20200609102615",
"Startdate": "20160101000000",
"Revision date": "20200609081113",
"Version": "1",
"Version description": "initial submission",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "10mn",
"Station code": "IT0004R",
"Platform code": "IT0004S",
"Station name": "Ispra",
"Station WDCA-ID": "GAWAIT__IPR",
"Station GAW-ID": "IPR",
"Station GAW-Name": "Ispra",
"Station land use": "Other",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "45.8",
"Station longitude": "8.633333",
"Station altitude": "209.0 m",
"Measurement height": "4.5 m",
"Regime": "IMG",
"Component": "aerosol_absorption_coefficient",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "IT04L",
"Instrument type": "filter_absorption_photometer",
"Instrument name": "MAAP-5012_B",
"Instrument manufacturer": "Thermo",
"Instrument model": "5012",
"Instrument serial number": "2310",
"Method ref": "IT04L_MAAP",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, Digitel, flow 220 l/min",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "Nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.5 1/Mm",
"Detection limit expl.": "Determined as 3*instrument noise, values below detection limit flagged 0.780",
"Measurement uncertainty": "6.0 %",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "IT04L, EC Joint Research Centre, EC-JRC-IES, Institute for Environment and Sustainability, Via Enrico Fermi 2749, , 21027, Ispra, Italy",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Martins dos Santos, Sebastiao, sebastiao.santos@ec.europa.eu, EC Joint Research Centre, EC-JRC, , Via Enrico Fermi 2749, , 21027, Ispra, Italy",
"Submitter": "Martins dos Santos, Sebastiao, sebastiao.santos@ec.europa.eu, EC Joint Research Centre, EC-JRC, , Via Enrico Fermi 2749, , 21027, Ispra, Italy",
"Comment": "No correction applied other than STP conversion"
}
|