citation |
- title:
- Ground based in situ observations of online_gc at Mt Cimone (IT0009R)
- dates:
- fileIdentifier:
- EBAS/IT0009R.20110102223100.20160718000000.online_gc..air.4y.2h.IT10L_GC-MS_6890-5975c_UNITY2-AIRSERVER2.IT10L_GPROSIM12_SETUPX1200.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "IT0009R.20110102223100.20160718000000.online_gc..air.4y.2h.IT10L_GC-MS_6890-5975c_UNITY2-AIRSERVER2.IT10L_GPROSIM12_SETUPX1200.lev2.nc",
"File creation": "20190514054811",
"Startdate": "20110102223100",
"Revision date": "20160718000000",
"Data level": "2",
"Period code": "4y",
"Resolution code": "2h",
"Sample duration": "40mn",
"Orig. time res.": "40mn",
"Station code": "IT0009R",
"Platform code": "IT0009S",
"Station name": "Mt Cimone",
"Station latitude": "44.183333",
"Station longitude": "10.7",
"Station altitude": "2165.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "IT10L",
"Instrument type": "online_gc",
"Instrument name": "GC-MS_6890-5975c_UNITY2-AIRSERVER2",
"Instrument manufacturer": "MARKES+MARKES+Agilent+Agilent",
"Instrument model": "Air Server+UNITY2+6890+5975C",
"Instrument serial number": "CIMxxxxx",
"Method ref": "IT10L_GPROSIM12_SETUPX1200",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit expl.": "Determined by data processing for each component evaluating the the S/N=3 on the blank chromatograms",
"Measurement uncertainty expl.": "Includes reproducibility (1/3 of DL + precision of the daily std measurements) + systematic errors (scale transfer), reported as expanded uncertainty 2sigma",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "IT10L, University of Urbino, , , , , , , ",
"Originator": "Arduini, Jgor, , , , , , , , , ",
"Submitter": "Arduini, Jgor, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "preconcentration on the Unity U-T5O3F-2S cold trap, O3 not removed directly, Nafion dryer is used, 2-hourly calibration interval, working std calibrated almost weekly against station std, regularly calibrated against NPL primary std at 0.5ppb"
}
|