citation |
- title:
- Ground based in situ observations of particle_number_concentration at Mt Cimone (IT0009R) using cpc
- dates:
- fileIdentifier:
- EBAS/IT0009R.20160101000000.20170930090000.cpc.particle_number_concentration.aerosol.1y.1h.IT06L_TSI_3772_CMN.IT06L_CPC_acquisition_lev0.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "IT0009R.20160101000000.20170930090000.cpc.particle_number_concentration.aerosol.1y.1h.IT06L_TSI_3772_CMN.IT06L_CPC_acquisition_lev0.lev2.nc",
"File creation": "20190514054400",
"Startdate": "20160101000000",
"Revision date": "20170930090000",
"Version": "1",
"Version description": "initial revision, CPC_acquisition_levmanually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "IT0009R",
"Platform code": "IT0009S",
"Station name": "Mt Cimone",
"Station latitude": "44.183333",
"Station longitude": "10.7",
"Station altitude": "2165.0 m",
"Measurement altitude": "2175.0 m",
"Measurement height": "10.0 m",
"Regime": "IMG",
"Component": "particle_number_concentration",
"Unit": "1/cm3",
"Matrix": "aerosol",
"Laboratory code": "IT06L",
"Instrument type": "cpc",
"Instrument name": "TSI_3772_CMN",
"Instrument manufacturer": "TSI",
"Instrument model": "3772",
"Instrument serial number": "70902011",
"Method ref": "IT06L_CPC_acquisition_lev0",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Humidity/temperature control": "Heating to 40% RH, limit 40 deg. C",
"Humidity/temperature control description": "head and sample heated from atmosphere to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "5.0 %",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "IT06L, CNR-ISAC, CNR-ISAC, Institute of Atmospheric Sciences and Climate, Via Gobetti 101, , 40129, Bologna, Italy",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Putero, Davide, d.putero@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy",
"Submitter": "Marinoni, Angela, , , , , , , , , ",
"Acknowledgement": "Request acknowledetails from data originator",
"Comment": "When p_int and T_int are not availabl, average p_int and T_int from the rest of the period are used to compute STP concentrations"
}
|