citation |
- title:
- Ground based in situ observations of nephelometer at Mt Cimone (IT0009R)
- dates:
- fileIdentifier:
- EBAS/IT0009R.20170101000000.20181011144600.nephelometer..aerosol.1y.1h.IT06L_Neph_TSI_3563133901.NO01L_scat_coef.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "IT0009R.20170101000000.20181011144600.nephelometer..aerosol.1y.1h.IT06L_Neph_TSI_3563133901.NO01L_scat_coef.lev2.nc",
"File creation": "20200430102650",
"Startdate": "20170101000000",
"Revision date": "20181011144600",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "IT0009R",
"Platform code": "IT0009S",
"Station name": "Mt Cimone",
"Station latitude": "44.183333",
"Station longitude": "10.7",
"Station altitude": "2165.0 m",
"Measurement latitude": "44.16667",
"Measurement longitude": "10.68333",
"Measurement altitude": "2165.0 m",
"Measurement height": "10.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "aerosol",
"Laboratory code": "IT06L",
"Instrument type": "nephelometer",
"Instrument name": "Neph_TSI_3563133901",
"Instrument manufacturer": "TSI",
"Instrument model": "3563",
"Instrument serial number": "3563133901",
"Method ref": "NO01L_scat_coef",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=Anderson1998",
"Inlet type": "Hat or hood",
"Inlet description": "Total particle size at ambient humidity inlet, heated head, home made followinfg EUSAAR design, flow 150 l/min",
"Humidity/temperature control": "Heating to 40% RH, limit 40 deg. C",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.5 1/Mm",
"Detection limit expl.": "Determined by instrument noise characteristics, no detection limit flag used",
"Measurement uncertainty": "0.5 1/Mm",
"Measurement uncertainty expl.": "average value taken from Anderson et al. 1996 for statistical and calibration uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "IT06L, Institute of Atmospheric Sciences and Climate, CNR-ISAC, Section of Bologna, Via Gobetti 101, , 40129, Bologna, Italy",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Naitza, Luca, l.naitza@isac.cnr.it, Institute of Atmospheric Sciences and Climate, ISAC, , Via P. Gobetti 101, , I-40129, Bologna, Italy",
"Submitter": "Marinoni, Angela, , , , , , , , , ",
"Acknowledgement": "Request contact to data originator",
"Comment": "None"
}
|