citation |
- title:
- Ground based in situ observations of ozone at Mt. Kenya (KE0001G) using uv_abs
- dates:
- fileIdentifier:
- EBAS/KE0001G.20190101000000.20210318121717.uv_abs.ozone.air.2y.1h.KE02L_TEI49C_no58106318.KE02L_uv_abs.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "KE0001G.20190101000000.20210318121717.uv_abs.ozone.air.2y.1h.KE02L_TEI49C_no58106318.KE02L_uv_abs.lev2.nc",
"File creation": "2021-03-19T02:20:39.970865 UTC",
"Export state": "2021-03-19T00:25:05.480000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20190101000000",
"Revision date": "20210318121717",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "KE0001G",
"Platform code": "KE0001S",
"Station name": "Mt. Kenya",
"Station WDCA-ID": "GAWAKE__MKN",
"Station GAW-ID": "MKN",
"Station GAW-Name": "Mt. Kenya",
"Station land use": "Grassland",
"Station setting": "Mountain",
"Station GAW type": "G",
"Station WMO region": "1",
"Station latitude": "-0.0622",
"Station longitude": "37.2972",
"Station altitude": "3678.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "KE02L",
"Instrument type": "uv_abs",
"Instrument name": "TEI49C_no58106318",
"Instrument manufacturer": "Thermo",
"Instrument model": "49C",
"Instrument serial number": "58106318",
"Method ref": "KE02L_uv_abs",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "inlet approx. 1.7 m above the cabin and 4.5 m above the ground and is permanently flushed by a high volume pump; residence times is below 10 s; sample air is taken from the manifold through a 1.5 m, 4 mm diameter teflon tubing at a flow rate of 2 lpm.",
"Inlet tube material": "Teflon",
"Maintenance description": "inlet filter (47 mm teflon filter (5 micron)) changed every 2 months",
"Flow rate": "2.0 l/min",
"Humidity/temperature control": "None",
"Absorption cross section": "1.1476e-17 cm2",
"QA1 measure ID": "WCC Empa Site Audit",
"QA1 date": "2019-12-13 UTC",
"QA1 outcome": "pass",
"Organization": "KE02L, Kenya Meteorological Department, KMD, Mt. Kenya GAW Station, P.O. Box 192, , 10400, Nanyuki, Kenya",
"Framework acronym": "GAW-WDCRG",
"Framework name": "World Data Centre for Reactive Gases",
"Framework description": "The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Njiru, David, njimdv@gmail.com, Kenya Meteorological Department, KMD, Mt Kenya GAW Station, P. O. Box 30259, , 00100, Nairobi GPO, Kenya",
"Submitter": "Steinbacher, Martin, martin.steinbacher@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|