citation |
- title:
- Ground based in situ observations of pm10_mass at Anmyeon-do (KR0100R) using beta_gauge_particulate_sampler
- dates:
- fileIdentifier:
- EBAS/KR0100R.20160101000000.20170905000000.beta_gauge_particulate_sampler.pm10_mass.pm10.39w.1h.KR04L_PM10_AMY01.KR04L_PM10.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "KR0100R.20160101000000.20170905000000.beta_gauge_particulate_sampler.pm10_mass.pm10.39w.1h.KR04L_PM10_AMY01.KR04L_PM10.lev2.nc",
"File creation": "20190514055717",
"Startdate": "20160101000000",
"Revision date": "20170905000000",
"Version": "1",
"Version description": "initial revision",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "39w",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "KR0100R",
"Platform code": "KR0100S",
"Station name": "Anmyeon-do",
"Station WDCA-ID": "GAWAKR__AMY",
"Station GAW-ID": "AMY",
"Station GAW-Name": "Anmyeon-do",
"Station land use": "Agricultural",
"Station setting": "Coastal",
"Station GAW type": "R",
"Station WMO region": "2",
"Station latitude": "36.5383338928",
"Station longitude": "126.330001831",
"Station altitude": "46.0 m",
"Measurement latitude": "36.53833",
"Measurement longitude": "126.33",
"Measurement altitude": "57.697 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "pm10_mass",
"Unit": "ug/m3",
"Matrix": "pm10",
"Laboratory code": "KR04L",
"Instrument type": "beta_gauge_particulate_sampler",
"Instrument name": "PM10_AMY01",
"Instrument manufacturer": "Thermo",
"Instrument model": "FH62C14",
"Instrument serial number": "0445",
"Method ref": "KR04L_PM10",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "inlet as delivered with instrument",
"Humidity/temperature control": "Other (see metadata)",
"Humidity/temperature control description": "Temperature conditioning at 40 deg C. Inlet tube heated to be 40 deg C",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "1.0 ug/m3",
"Detection limit expl.": "Determined by manufacturer",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "typical deviation to impactor and filter reference methods as determined by Burkartetal.,2010.",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "detection limit is 1ug/m3",
"Organization": "KR04L, Korea Meteorological Administration, KMA/NIMS, National Institute of Meteorological Sciences, 33 Seohobuk-ro, Seogwipo-si, 63568, Jeju-do, Republic of Korea",
"Frameworks": "GAW-WDCA",
"Originator": "Ryoo, Sangboom, sbryoo@korea.kr, National Institute of Meteorological Sciences, KMA/NIMS, Environmental Meteorology Research Division, 33 Seohobuk-ro, Seogwipo-si, 63568, Jeju-do, Republic of Korea",
"Submitter": "KMA, CCMD, cl.ccmd@korea.kr, Korea Meteorological Administration, KMA CCMD, Climate Change Monitoring Division, 61 Yeouidaebangro 16gil, Dongjak-gu, 07062, Seoul, Republic of Korea",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Instrument installed and operated according to manual"
}
|