citation |
- title:
- Ground based in situ observations of particle_number_concentration at Gosan (KR0101R) using cpc
- dates:
- fileIdentifier:
- EBAS/KR0101R.20180101000000.20191220000000.cpc.particle_number_concentration.pm10.1y.1h.KR04L_TSI_3772_JGS.KR04L_TSICPC3772.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "KR0101R.20180101000000.20191220000000.cpc.particle_number_concentration.pm10.1y.1h.KR04L_TSI_3772_JGS.KR04L_TSICPC3772.lev2.nc",
"File creation": "20200203112558",
"Startdate": "20180101000000",
"Revision date": "20191220000000",
"Version": "1",
"Version description": "initial revision",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "5mn",
"Station code": "KR0101R",
"Platform code": "KR0101S",
"Station name": "Gosan",
"Station GAW-ID": "JGS",
"Station land use": "Grassland",
"Station setting": "Coastal",
"Station GAW type": "R",
"Station WMO region": "2",
"Station latitude": "33.293917",
"Station longitude": "126.163111",
"Station altitude": "71.0 m",
"Measurement latitude": "33.2925",
"Measurement longitude": "126.1617",
"Measurement altitude": "71.0 m",
"Measurement height": "8.0 m",
"Regime": "IMG",
"Component": "particle_number_concentration",
"Unit": "1/cm3",
"Matrix": "pm10",
"Laboratory code": "KR04L",
"Instrument type": "cpc",
"Instrument name": "TSI_3772_JGS",
"Instrument manufacturer": "TSI",
"Instrument model": "3772",
"Instrument serial number": "71014239",
"Method ref": "KR04L_TSICPC3772",
"Standard method": "None",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, flow 16.7 l/min",
"Humidity/temperature control": "Diffusion dryer",
"Humidity/temperature control description": "both temperature conditioning at 30 deg C and diffusion dryer used",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "5.0 %",
"Measurement uncertainty expl.": "typical value of unit-to-unit variability",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"QA1 measure ID": "WCCAP-CPC-2018-6",
"QA1 date": "20180921",
"QA1 document URL": "http://www.actris-ecac.eu/files/ECAC-report-CPC-2018-6-5.pdf",
"Organization": "KR04L, Korea Meteorological Administration, KMA/NIMS, National Institute of Meteorological Sciences, 33 Seohobuk-ro, Seogwipo-si, 63568, Jeju-do, Republic of Korea",
"Frameworks": "GAW-WDCA",
"Originator": "Kim, Jeongeun, narci76@korea.kr, National Institute of Meteorological Sciences, KMA/NIMS, Environmental Meteorology Research Division, 33 Seohobuk-ro, Seogwipo-si, 63568, Jeju-do, Republic of Korea",
"Submitter": "Kim, Jeongeun, narci76@korea.kr, National Institute of Meteorological Sciences, KMA/NIMS, Environmental Meteorology Research Division, 33 Seohobuk-ro, Seogwipo-si, 63568, Jeju-do, Republic of Korea",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "Aerosol diluter (TSI 3302) of 1 to 20 was used until 2018032808 UTC, diffusion dryer used during 2018010100~2018121004(UTC), Nafion dryer applied from 2018121005(UTC)"
}
|