citation |
- title:
- Ground based in situ observations of b-attenuation at Rucava (LV0010R)
- dates:
- fileIdentifier:
- EBAS/LV0010R.20181231000000.20200606140000.b-attenuation..pm25.53w.1w.LV33L_LEGMC_opsis_0010_pm25.LV33L_LEGMC_Dionex_ICS-3000.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "LV0010R.20181231000000.20200606140000.b-attenuation..pm25.53w.1w.LV33L_LEGMC_opsis_0010_pm25.LV33L_LEGMC_Dionex_ICS-3000.lev2.nc",
"File creation": "20201112214535",
"Startdate": "20181231000000",
"Revision date": "20200606140000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "53w",
"Resolution code": "1w",
"Sample duration": "1w",
"Orig. time res.": "1d",
"Station code": "LV0010R",
"Platform code": "LV0010S",
"Station name": "Rucava",
"Station latitude": "56.161944",
"Station longitude": "21.173056",
"Station altitude": "18.0 m",
"Measurement altitude": "18.0 m",
"Measurement height": "3.0 m",
"Regime": "IMG",
"Unit": "ug/m3",
"Matrix": "pm25",
"Laboratory code": "LV33L",
"Instrument type": "b-attenuation",
"Instrument name": "LEGMC_opsis_0010_pm25",
"Instrument manufacturer": "Opsis",
"Instrument model": "SM200",
"Instrument serial number": "1263",
"Analytical laboratory code": "LV33L",
"Analytical measurement technique": "IC",
"Analytical instrument name": "LEGMC_Dionex_ICS-3000",
"Analytical instrument manufacturer": "Dionex",
"Analytical instrument model": "ICS-3000",
"Analytical instrument serial number": "07010332",
"Method ref": "LV33L_LEGMC_Dionex_ICS-3000",
"Inlet type": "Selective filtration",
"Flow rate": "38.33 l/min",
"Medium": "Teflon",
"Sample preparation": "Water extraction after ultrasonic treatment",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "Heating to 40% RH, limit 40 deg. C",
"Detection limit expl.": "determined by taking 3 times standard deviation of ensemble of laboratory blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as detection limit of laboratory blanks, flagged with 781",
"Organization": "LV33L, \"Latvian Environment, Geology and Meteorology Centre\", , Monitoring Department, Maskavas Str. 165, , LV-1019, Riga, Latvia",
"Framework acronym": "GAW-WDCA, EMEP_preliminary",
"Framework name": "World Data Centre for Aerosols, Preliminary data submissions for European Monitoring and Evaluation Programme",
"Framework description": "The World Data Centre for Aerosols is the data repository and archive for microphysical, optical, and chemical properties of atmospheric aerosol of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme., The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Markus Fiebig, Kjetil Tørseth",
"Framework contact email": "Markus.Fiebig@nilu.no, kt@nilu.no",
"Originator": "Indriksone, Iveta, , , , , , , , , ",
"Submitter": "Frolova, Marina, , , , , , , , , "
}
|