citation |
- title:
- Ground based in situ observations of low_vol_sampler at Bilthoven (NL0008R)
- dates:
- fileIdentifier:
- EBAS/NL0008R.20190101010000.20211110133706.low_vol_sampler..pm10.2y.1d.NL01L_HM_627.NL01L_MIL-W-5200_NL01L_ILG-W-2902_NEN12341.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "NL0008R.20190101010000.20211110133706.low_vol_sampler..pm10.2y.1d.NL01L_HM_627.NL01L_MIL-W-5200_NL01L_ILG-W-2902_NEN12341.lev2.nc",
"File creation": "2021-11-10T18:03:30.319822 UTC",
"Export state": "2021-11-10T17:25:03.457000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20190101010000",
"Revision date": "20211110133706",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "NL0008R",
"Platform code": "NL0008S",
"Station name": "Bilthoven",
"Station latitude": "52.116667",
"Station longitude": "5.2",
"Station altitude": "5.0 m",
"Measurement altitude": "3.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Matrix": "pm10",
"Laboratory code": "NL01L",
"Instrument type": "low_vol_sampler",
"Instrument name": "HM_627",
"Instrument manufacturer": "Leckel",
"Instrument model": "SEQ47/50",
"Analytical laboratory code": "NL05L",
"Analytical measurement technique": "ICP-HRMS",
"Analytical instrument name": "ICP-HRMS",
"Method ref": "NL01L_MIL-W-5200_NL01L_ILG-W-2902_NEN12341",
"Flow rate": "38.3125 l/min",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"Organization": "NL01L, Rijks institut voor volksgezondheid en milieuhygiene, RIVM, , \"Antoine van Leeuwenhoeklaan 9, Postbus 1, NL-3720 BA BILTHOVEN, The Netherlands\", , , , ",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Spoor, Ronald, , , , , , , , , ",
"Submitter": "Wietses, Mirian, mirian.wietses@rivm.nl, Rijks instituut voor volksgezondheid en milieu, RIVM, ILG, P.O. Box 1, , 3720BA, Bilthoven, Netherlands"
}
|