citation |
- title:
- Ground based in situ observations of sulphur_dioxide at Birkenes II (NO0002R) using filter_3pack
- dates:
- fileIdentifier:
- EBAS/NO0002R.20191229000000.20200310094127.filter_3pack.sulphur_dioxide.air.2w.2w.NO01L_rita_slett1.NO01L_IC.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "NO0002R.20191229000000.20200310094127.filter_3pack.sulphur_dioxide.air.2w.2w.NO01L_rita_slett1.NO01L_IC.lev2.nc",
"File creation": "20200310112745",
"Startdate": "20191229000000",
"Revision date": "20200310094127",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2w",
"Resolution code": "2w",
"Station code": "NO0002R",
"Platform code": "NO0002S",
"Station name": "Birkenes II",
"Station WDCA-ID": "GAWANO__BIR",
"Station GAW-ID": "BIR",
"Station GAW-Name": "Birkenes Atmospheric Observatory",
"Station land use": "Forest",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "58.38853",
"Station longitude": "8.252",
"Station altitude": "219.0 m",
"Regime": "IMG",
"Component": "sulphur_dioxide",
"Unit": "ug S/m3",
"Matrix": "air",
"Laboratory code": "NO01L",
"Instrument type": "filter_3pack",
"Instrument name": "rita_slett1",
"Analytical laboratory code": "NO01L",
"Analytical measurement technique": "IC",
"Analytical instrument name": "IC",
"Analytical instrument manufacturer": "Dionex",
"Analytical instrument model": "ICS-2100",
"Method ref": "NO01L_IC",
"Standard method": "SOP=EMEP_manual_v1996",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing",
"Flow rate": "17.4 l/min",
"Medium": "Cellulose",
"Coating/Solution": "KOH",
"Sample preparation": "Water extraction after ultrasonic treatment",
"Blank correction": "Blank corrected",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions together with sampling head.",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit": "0.01 ug S/m3",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of field blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"QA1 measure ID": "EMEP36",
"QA1 date": "20181201",
"QA1 outcome": "pass",
"QA1 bias": "-8.92 %",
"QA1 variability": "5.07 %",
"QA1 document name": "Summary statistics EMEP laboratory intercalibration Round 36",
"QA1 document date": "20180327",
"QA1 document URL": "https://projects.nilu.no/ccc/qameasure/emep36.pdf",
"Organization": "NO01L, Norwegian Institute for Air Research, NILU, , Instituttveien 18, , 2007, Kjeller, Norway",
"Frameworks": "NILU",
"Originator": "Aas, Wenche, waa@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway",
"Submitter": "Hjellbrekke, Anne, agh@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway"
}
|