citation |
- title:
- Ground based in situ observations of online_crds at Birkenes II (NO0002R)
- dates:
- fileIdentifier:
- EBAS/NO0002R.20210101000000.20220329000000.online_crds..air.1y.1h.NO01L_CFKADS2262.NO01L_picarro_tower.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "NO0002R.20210101000000.20220329000000.online_crds..air.1y.1h.NO01L_CFKADS2262.NO01L_picarro_tower.lev2.nc",
"File creation": "2022-05-13T16:39:16.913382 UTC",
"Export state": "2022-05-13T16:25:03.147000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20210101000000",
"Revision date": "20220329000000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1s",
"Station code": "NO0002R",
"Platform code": "NO0002S",
"Station name": "Birkenes II",
"Station WDCA-ID": "GAWANO__BIR",
"Station GAW-ID": "BIR",
"Station GAW-Name": "Birkenes Atmospheric Observatory",
"Station other IDs": "BIR (ICOS), Birkenes (AERONET)",
"Station land use": "Forest",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "6",
"Station latitude": "58.38853",
"Station longitude": "8.252",
"Station altitude": "219.0 m",
"Measurement altitude": "219.0 m",
"Regime": "IMG",
"Matrix": "air",
"Laboratory code": "NO01L",
"Instrument type": "online_crds",
"Instrument name": "CFKADS2262",
"Instrument manufacturer": "Picarro",
"Instrument model": "G2401",
"Instrument serial number": "CFKADS2262",
"Method ref": "NO01L_picarro_tower",
"Calibration standard ID": "ICOS",
"Secondary standard ID": "ICOS",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood. Insulated, heated",
"Inlet tube material": "Stainless steel",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "Sample dried using nafion dryer.",
"Detection limit expl.": "Lower limit of operating range",
"Measurement uncertainty expl.": "Max Uncertainty using Reference Gas (1 hr average, 2s)",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Zero and neg. values will not appear",
"Organization": "NO01L, Norwegian Institute for Air Research, NILU, , Instituttveien 18, , 2007, Kjeller, Norway",
"Framework acronym": "EMEP, NILU",
"Framework name": "European Monitoring and Evaluation Programme, Norwegian Institute for Air Research",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., Atmospheric measuremnts produced at NILU.",
"Framework contact name": "Kjetil Tørseth, Kjetil Tørseth",
"Framework contact email": "kt@nilu.no, kt@nilu.no",
"Originator": "Platt, Stephen Matthew, sp@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway, ORCID=0000-0003-3587-5926",
"Submitter": "Lunder, Chris, crl@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "SOP currently not available"
}
|