citation |
- title:
- Ground based in situ observations of carbon_dioxide at Zeppelin mountain (Ny-Ålesund) (NO0042G) using online_crds
- dates:
- fileIdentifier:
- EBAS/NO0042G.20160101000000.20220701065819.online_crds.carbon_dioxide.air.6y.1h.NO01L_picarro2_G2401.NO01L_picarro.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "NO0042G.20160101000000.20220701065819.online_crds.carbon_dioxide.air.6y.1h.NO01L_picarro2_G2401.NO01L_picarro.lev2.nc",
"File creation": "2022-07-01T17:09:59.693561 UTC",
"Export state": "2022-07-01T16:25:03.113000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20160101000000",
"Revision date": "20220701065819",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "6y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1s",
"Station code": "NO0042G",
"Platform code": "NO0042S",
"Station name": "Zeppelin mountain (Ny-Ålesund)",
"Station WDCA-ID": "GAWANO__ZEP",
"Station GAW-ID": "ZEP",
"Station GAW-Name": "Zeppelin Mountain (Ny Ålesund)",
"Station land use": "Gravel and stone",
"Station setting": "Polar",
"Station GAW type": "G",
"Station WMO region": "6",
"Station latitude": "78.90715",
"Station longitude": "11.88668",
"Station altitude": "474.0 m",
"Measurement altitude": "489.0 m",
"Measurement height": "15.0 m",
"Regime": "IMG",
"Component": "carbon_dioxide",
"Unit": "umol/mol",
"Matrix": "air",
"Laboratory code": "NO01L",
"Instrument type": "online_crds",
"Instrument name": "picarro2_G2401",
"Instrument manufacturer": "Picarro",
"Instrument model": "G2401",
"Instrument serial number": "CFKADS2093",
"Method ref": "NO01L_picarro",
"Calibration scale": "WMO CO2 X2007",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood. Insulated, heated",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "Sample dried using nafion dryer.",
"Detection limit": "0.0 umol/mol",
"Detection limit expl.": "Lower limit of operating range",
"Measurement uncertainty": "0.05 umol/mol",
"Zero/negative values code": "Zero/negative impossible",
"Zero/negative values": "Zero and neg. values will not appear",
"Organization": "NO01L, Norwegian Institute for Air Research, NILU, , Instituttveien 18, , 2007, Kjeller, Norway",
"Framework acronym": "NILU",
"Framework name": "Norwegian Institute for Air Research",
"Framework description": "Atmospheric measuremnts produced at NILU.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Lund-Myhre, Cathrine, clm@nilu.no, Norwegian Institute for Air Research, NILU, ATMOS, Instituttveien 18, , N-2027, Kjeller, Norway",
"Submitter": "Hermansen, Ove, oh@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway, ORCID=0000-0001-7353-057X",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|