citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Zeppelin mountain (Ny-Ålesund) (NO0042G) using dmps
- dates:
- fileIdentifier:
- EBAS/NO0042G.20160506050000.20200507201551.dmps.particle_number_size_distribution.aerosol.20mo.1h.NO01L_NILU_DMPSmodel2_ZEP.NO01L_dmps_DMPS_ZEP01.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "NO0042G.20160506050000.20200507201551.dmps.particle_number_size_distribution.aerosol.20mo.1h.NO01L_NILU_DMPSmodel2_ZEP.NO01L_dmps_DMPS_ZEP01.lev2.nc",
"File creation": "20200508032401",
"Startdate": "20160506050000",
"Revision date": "20200507201551",
"Version": "1",
"Version description": "initial revision, DMPS_CCNC_control_v0.0.6, Adis_DMPS_lev1_2_lev2_0_2_0",
"Data level": "2",
"Period code": "20mo",
"Resolution code": "1h",
"Sample duration": "1h",
"Station code": "NO0042G",
"Platform code": "NO0042S",
"Station name": "Zeppelin mountain (Ny-Ålesund)",
"Station WDCA-ID": "GAWANO__ZEP",
"Station GAW-ID": "ZEP",
"Station GAW-Name": "Zeppelin Mountain (Ny Ålesund)",
"Station land use": "Gravel and stone",
"Station setting": "Polar",
"Station GAW type": "G",
"Station WMO region": "6",
"Station latitude": "78.90715",
"Station longitude": "11.88668",
"Station altitude": "474.0 m",
"Measurement latitude": "78.90669",
"Measurement longitude": "11.88934",
"Measurement altitude": "475.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "aerosol",
"Laboratory code": "NO01L",
"Instrument type": "dmps",
"Instrument name": "NILU_DMPSmodel2_ZEP",
"Instrument manufacturer": "NILU",
"Instrument model": "DMPSmodel2",
"Instrument serial number": "00001/4",
"Method ref": "NO01L_dmps_DMPS_ZEP01",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Hat or hood",
"Inlet description": "Vertical inlet tube with head and main flow, equipped with take-offs.PM10 at ambient humidity inlet",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.006 1/cm3",
"Detection limit expl.": "Determined only by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "NO01L, Norwegian Institute for Air Research, NILU, , Instituttveien 18, , 2007, Kjeller, Norway",
"Frameworks": "ACTRIS EMEP GAW-WDCA NILU",
"Originator": "Lunder, Chris, crl@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway",
"Submitter": "Lunder, Chris, crl@nilu.no, Norwegian Institute for Air Research, NILU, Atmosphere and Climate Department, Instituttveien 18, , 2007, Kjeller, Norway",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "None"
}
|