citation |
- title:
- Ground based in situ observations of ozone at Huancayo (PE0001R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/PE0001R.20140101000000.20211124122233.uv_abs.ozone.air.6y.1h.PE01L_PE01_uv_abs_IGP.PE01L_uv_ab.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "PE0001R.20140101000000.20211124122233.uv_abs.ozone.air.6y.1h.PE01L_PE01_uv_abs_IGP.PE01L_uv_ab.lev2.nc",
"File creation": "2021-11-24T19:53:32.393279 UTC",
"Export state": "2021-11-24T17:25:02.840000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20140101000000",
"Revision date": "20211124122233",
"Version": "1",
"Version description": "initial revision,manually inspected",
"Data level": "2",
"Period code": "6y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "PE0001R",
"Platform code": "PE0001S",
"Station name": "Huancayo",
"Station GAW-ID": "HUA",
"Station land use": "Agricultural",
"Station setting": "Rural",
"Station GAW type": "R",
"Station WMO region": "3",
"Station latitude": "-12.0402",
"Station longitude": "-75.3209",
"Station altitude": "3313.0 m",
"Measurement altitude": "3320.0 m",
"Measurement height": "6.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "PE01L",
"Instrument type": "uv_abs",
"Instrument name": "PE01_uv_abs_IGP",
"Instrument manufacturer": "Ansyco",
"Instrument model": "41M",
"Instrument serial number": "356",
"Method ref": "PE01L_uv_ab",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "Inlet approx. 3 m above the building and 6 m above the ground; coarse mesh at the top of the inlet to protect against spiders etc.; 47 mm teflon filter (2 micron) just upstream of the instrument inlet.",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "47.0 mm",
"Inlet tube length": "3.0 m",
"Maintenance description": "Anunal leak test, inlet filter checked every 3 months, ozone scrubber checked and replaced if needed once/year",
"Flow rate": "0.5 l/min",
"Zero/span check type": "automatic",
"Zero/span check interval": "1d",
"Humidity/temperature control": "None",
"Absorption cross section": "1.1476e-17 cm2",
"QA1 measure ID": "WCC Empa Site Audit",
"QA1 date": "2012-09-02 UTC",
"QA1 document URL": "https://www.empa.ch/documents/56101/250799/Zeppelin_Mt12.pdf",
"Organization": "PE01L, Geophysical Institute of Peru, IGP, , \"Ca. Badajoz 169, Ate\", , 15012, Lima, Peru",
"Framework acronym": "EMEP, GAW-WDCRG",
"Framework name": "European Monitoring and Evaluation Programme, World Data Centre for Reactive Gases",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth, Kjetil Tørseth",
"Framework contact email": "kt@nilu.no, kt@nilu.no",
"Originator": "Torres, Christian, christian010194@gmail.com, Federal University of Rio Grande, FURG, Institute of Oceanography, Italia Km 8, , 96203-900, Rio Grande, Brasil",
"Submitter": "Suarez-Salas, Luis, lsuarez@igp.gob.pe, Geophysical Institute of Peru, IGP, Laboratorio de Microfísica Atmosférica y Radiación, Ca. Badajoz 169, , 15012, Lima, Peru",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|