citation |
- title:
- Ground based in situ observations of high_vol_sampler at Diabla Gora (PL0005R)
- dates:
- fileIdentifier:
- EBAS/PL0005R.20160101000000.20211110095545.high_vol_sampler..pm25.5y.1d.PL02L_HVPM25.PL22L_p05_therm-opt.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "PL0005R.20160101000000.20211110095545.high_vol_sampler..pm25.5y.1d.PL02L_HVPM25.PL22L_p05_therm-opt.lev2.nc",
"File creation": "2021-11-10T20:02:50.688074 UTC",
"Export state": "2021-11-10T17:25:03.457000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20160101000000",
"Revision date": "20211110095545",
"Data level": "2",
"Period code": "5y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "PL0005R",
"Platform code": "PL0005S",
"Station name": "Diabla Gora",
"Station latitude": "54.15",
"Station longitude": "22.066667",
"Station altitude": "157.0 m",
"Measurement altitude": "159.0 m",
"Measurement height": "2.0 m",
"Regime": "IMG",
"Unit": "ug C/m3",
"Matrix": "pm25",
"Laboratory code": "PL02L",
"Instrument type": "high_vol_sampler",
"Instrument name": "HVPM25",
"Instrument manufacturer": "DIGITEL",
"Instrument model": "DHA-80",
"Instrument serial number": "PP-BN-63",
"Analytical laboratory code": "PL22L",
"Analytical measurement technique": "thermal-optical_analysis",
"Analytical instrument name": "p05_therm-opt",
"Analytical instrument manufacturer": "Sunset Laboratory",
"Analytical instrument model": "OCEC Lab Instrument Model 4L",
"Analytical instrument serial number": "254-54",
"Method ref": "PL22L_p05_therm-opt",
"Standard method": "SOP=EMEP_manual_v2014, TEMP=EUSAAR_2",
"Inlet type": "Impactor--direct",
"Flow rate": "500.0 l/min",
"Filter face velocity": "54.1 cm/s",
"Exposed filter area": "154.0 cm2",
"Filter description": "Whatman QMA 150 mm",
"Medium": "Quartz",
"Filter prefiring": "Not prefired",
"Filter conditioning": "293.0 K, 50.0 %RH, 48.0 h",
"Sample preparation": "None",
"Blank correction": "Blank corrected",
"Artifact correction": "None",
"Humidity/temperature control": "None",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of laboratory blanks",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero/negative values reported as measured if within detection limit, flagged with 780",
"Organization": "PL02L, Institute of Environmental Protection - National Research Institute, IEP-NRI, , Kolektorska 4, , 01-692, Warsaw, Poland",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Degorska, Anna, , , , , , , , , ",
"Submitter": "Degorska, Anna, , , , , , , , , "
}
|