citation |
- title:
- Ground based in situ observations of total_gaseous_mercury at Diabla Gora (PL0005R) using gold_trap
- dates:
- fileIdentifier:
- EBAS/PL0005R.20170105060000.20191025111304.gold_trap.total_gaseous_mercury.air.2y.1w.PL02L_ads_05.PL02L_BL_AMA254.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "PL0005R.20170105060000.20191025111304.gold_trap.total_gaseous_mercury.air.2y.1w.PL02L_ads_05.PL02L_BL_AMA254.lev2.nc",
"File creation": "20201112215434",
"Startdate": "20170105060000",
"Revision date": "20191025111304",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1w",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "PL0005R",
"Platform code": "PL0005S",
"Station name": "Diabla Gora",
"Station latitude": "54.15",
"Station longitude": "22.066667",
"Station altitude": "157.0 m",
"Regime": "IMG",
"Component": "total_gaseous_mercury",
"Unit": "ng/m3",
"Matrix": "air",
"Laboratory code": "PL02L",
"Instrument type": "gold_trap",
"Instrument name": "ads_05",
"Instrument manufacturer": "IVL",
"Instrument model": "ads_tube",
"Analytical laboratory code": "PL02L",
"Analytical measurement technique": "AAS",
"Analytical instrument name": "BL_AMA254",
"Analytical instrument manufacturer": "SpectroLab",
"Analytical instrument model": "AMA 254",
"Method ref": "PL02L_BL_AMA254",
"Standard method": "SOP=EMEP_manual_v2014",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing",
"Medium": "Gold",
"Sample preparation": "Thermal desorption",
"Blank correction": "Not blank corrected",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions",
"Volume std. temperature": "ambient",
"Volume std. pressure": "ambient",
"Detection limit": "1.0 ng/m3",
"Detection limit expl.": "Determined by taking 3 times standard deviation of ensemble of laboratory blanks",
"Organization": "PL02L, Institute of Environmental Protection - National Research Institute, IEP-NRI, , Kolektorska 4, , 01-692, Warsaw, Poland",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Degorska, Anna, , , , , , , , , ",
"Submitter": "Degorska, Anna, , , , , , , , , ",
"Acknowledgement": "Chief Inspectorate of Environmental Protection, Departament of Monitoring and Information on Environment, Wawelska 52/54, 00-922 Warsaw, Poland, sekretariatdm@gios.gov.pl"
}
|