citation |
- title:
- Ground based in situ observations of online_gc at Pico, Azores (PT0007R)
- dates:
- fileIdentifier:
- EBAS/PT0007R.20040101000000.20170713000000.online_gc..air.10y.238mn.US13L_sri_8610_pt07.US13L_PCOSRI.lev1.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "PT0007R.20040101000000.20170713000000.online_gc..air.10y.238mn.US13L_sri_8610_pt07.US13L_PCOSRI.lev1.nc",
"File creation": "20190827183310",
"Startdate": "20040101000000",
"Revision date": "20170713000000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "1",
"Period code": "10y",
"Resolution code": "238mn",
"Sample duration": "40mn",
"Orig. time res.": "40mn",
"Station code": "PT0007R",
"Platform code": "PT0007S",
"Station name": "Pico, Azores",
"Station land use": "Gravel and stone",
"Station setting": "Mountain",
"Station WMO region": "6",
"Station latitude": "38.4675555556",
"Station longitude": "-28.4017222222",
"Station altitude": "2225.0 m",
"Measurement height": "7.0 m",
"Regime": "IMG",
"Unit": "pmol/mol",
"Matrix": "air",
"Laboratory code": "US13L",
"Instrument type": "online_gc",
"Instrument name": "sri_8610_pt07",
"Instrument manufacturer": "SRI",
"Instrument model": "8610 GC",
"Method ref": "US13L_PCOSRI",
"Standard method": "None",
"Inlet type": "Hat or hood",
"Inlet description": "Downward facing with hood",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.004 pmol/mol",
"Detection limit expl.": "Detection limits based on regularly observed blank values that interfere with accurate sample integration.",
"Measurement uncertainty expl.": "Uncertainty is standard reproducibility over 1-month periods that determine response factors. Uncertainty is 5% of given values for ethane, 6% for propane and i-butane, 7% for n-butane, 10% for i-pentane, 14% for n-pentane, and 18% for acetylene.",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "US13L, University of Colorado - INSTAAR, INSTAAR, Institute of Arctic and Alpine Research, \"4001 Discovery Drive, Rm N202\", , CO 80303, Boulder, USA",
"Frameworks": "Independent",
"Originator": "Hueber, Jacques, Jacques.hueber@colorado.edu, Institute of Artic and Alpine Research, INSTAAR, Atmospheric Research Lab, 4001 Discovery Drive, , 80303, Boulder Colorado, United States",
"Submitter": "Blanchard, Brendan, Brendan.blanchard@colorado.edu, Institute of Artic and Alpine Research, INSTAAR, Atmospheric Research Lab, 4001 Discovery Drive, , 80303, Boulder Colorado, United States",
"Acknowledgement": "This project was supported in part by NSF grants INT-0110397, ATM-0215843, and ATM-0720955."
}
|