citation |
- title:
- Ground based in situ observations of nephelometer at Vavihill (SE0011R)
- dates:
- fileIdentifier:
- EBAS/SE0011R.20140101000000.20160704074117.nephelometer..pm10.1y.1h.SE04L_ECOTECHneph_Vavihill01.SE04L_scat_coef.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "SE0011R.20140101000000.20160704074117.nephelometer..pm10.1y.1h.SE04L_ECOTECHneph_Vavihill01.SE04L_scat_coef.lev2.nc",
"File creation": "20190514085018",
"Startdate": "20140101000000",
"Revision date": "20160704074117",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "SE0011R",
"Platform code": "SE0011S",
"Station name": "Vavihill",
"Station latitude": "56.016667",
"Station longitude": "13.15",
"Station altitude": "175.0 m",
"Measurement latitude": "56.016667",
"Measurement longitude": "13.15",
"Measurement altitude": "172.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Unit": "1/Mm",
"Matrix": "pm10",
"Laboratory code": "SE04L",
"Instrument type": "nephelometer",
"Instrument name": "ECOTECHneph_Vavihill01",
"Instrument manufacturer": "Ecotech",
"Instrument model": "Aurora3000",
"Method ref": "SE04L_scat_coef",
"Standard method": "cal-gas=CO2+AIR_truncation-correction=Anderson1998",
"Inlet type": "Impactor--direct",
"Inlet description": "PM10 at ambient humidity inlet, flow 17 l/min",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "passive, sample heated from atmospheric to lab temperature",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.3 1/Mm",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "0.5 1/Mm",
"Measurement uncertainty expl.": "average value taken from Anderson et al. 1996 for statistical and calibration uncertainty",
"Zero/negative values code": "Zero/negative possible",
"Zero/negative values": "Zero and neg. values may appear due to statistical variations at very low concentrations",
"Organization": "SE04L, Lund University, , , Box 118, , S-2210, Lund, Sweden",
"Frameworks": "ACTRIS EMEP GAW-WDCA",
"Originator": "Swietlicki, Erik, , , , , , , , , ",
"Submitter": "Ahlberg, Erik, erik.ahlberg@nuclear.lu.se, Lund University, ULund, , , Box 118, SE-221 0, Lund, Sweden",
"Comment": "Truncation correction based on Anderson & Ogren 1998 but with coefficient based on linear fit of truncation correction. Request details from data originator"
}
|