citation |
- title:
- Ground based in situ observations of particle_number_size_distribution at Aspvreten (SE0012R) using dmps
- dates:
- fileIdentifier:
- EBAS/SE0012R.20140101000000.20171019120032.dmps.particle_number_size_distribution.aerosol.1y.1h.SE02L_ITM_new_haddok_ASP.SE02L_DMPS_EUSAAR.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "SE0012R.20140101000000.20171019120032.dmps.particle_number_size_distribution.aerosol.1y.1h.SE02L_ITM_new_haddok_ASP.SE02L_DMPS_EUSAAR.lev2.nc",
"File creation": "20190514085547",
"Startdate": "20140101000000",
"Revision date": "20171019120032",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "15mn",
"Station code": "SE0012R",
"Platform code": "SE0012S",
"Station name": "Aspvreten",
"Station latitude": "58.8",
"Station longitude": "17.383333",
"Station altitude": "20.0 m",
"Measurement latitude": "58.8058",
"Measurement longitude": "17.3834",
"Measurement altitude": "20.0 m",
"Measurement height": "4.0 m",
"Regime": "IMG",
"Component": "particle_number_size_distribution",
"Unit": "1/cm3",
"Matrix": "aerosol",
"Laboratory code": "SE02L",
"Instrument type": "dmps",
"Instrument name": "ITM_new_haddok_ASP",
"Instrument manufacturer": "ITM",
"Instrument model": "New_Haddock",
"Instrument serial number": "NaN",
"Method ref": "SE02L_DMPS_EUSAAR",
"Standard method": "SOP=Wiedensohler2012",
"Inlet type": "Downward-facing tube",
"Inlet description": "Whole air",
"Humidity/temperature control": "Nafion dryer",
"Humidity/temperature control description": "Nafion dryer",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.0 1/cm3",
"Detection limit expl.": "Determined by instrument counting statistics, no detection limit flag used",
"Measurement uncertainty": "10.0 %",
"Measurement uncertainty expl.": "certainty range between instruments in intercomparison by Wiedensohler et al. 2012.",
"Zero/negative values code": "Zero possible",
"Zero/negative values": "Zero values may appear due to statistical variations at very low concentrations",
"Organization": "SE02L, \"Institute of Applied Environmental Research (Air Pollution Laboratory), Stockholm University\", , , \"Frescativägen 54, S-106 91 STOCKHOLM, Sweden\", , , , ",
"Frameworks": "ACTRIS GAW-WDCA",
"Originator": "Areskoug, Hans, , , , , , , , , ",
"Submitter": "Areskoug, Hans, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator",
"Comment": "SOP=Wiedensohler2012"
}
|