citation |
- title:
- Ground based in situ observations of pm10_mass at Iskrba (SI0008R) using low_vol_sampler
- dates:
- fileIdentifier:
- EBAS/SI0008R.20150101073000.20211102090000.low_vol_sampler.pm10_mass.pm10.6y.1d.SI01L_Leckel.SI01L_pm_mas2.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TI",
"Timezone": "UTC",
"File name": "SI0008R.20150101073000.20211102090000.low_vol_sampler.pm10_mass.pm10.6y.1d.SI01L_Leckel.SI01L_pm_mas2.lev2.nc",
"File creation": "2021-11-10T20:03:28.644089 UTC",
"Export state": "2021-11-10T17:25:03.457000 UTC",
"Export filter": "exclude-900,exclude-invalid",
"Startdate": "20150101073000",
"Revision date": "20211102090000",
"Version description": "initial revision, manually inspected",
"Statistics": "arithmetic mean",
"Data level": "2",
"Period code": "6y",
"Resolution code": "1d",
"Sample duration": "1d",
"Orig. time res.": "1d",
"Station code": "SI0008R",
"Platform code": "SI0008S",
"Station name": "Iskrba",
"Station latitude": "45.566667",
"Station longitude": "14.866667",
"Station altitude": "520.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Component": "pm10_mass",
"Unit": "ug/m3",
"Matrix": "pm10",
"Laboratory code": "SI01L",
"Instrument type": "low_vol_sampler",
"Instrument name": "Leckel",
"Instrument manufacturer": "Leckel",
"Instrument model": "SEQ47/50",
"Method ref": "SI01L_pm_mas2",
"Standard method": "SOP=EMEP_manual_v1996",
"Inlet description": "size selective inlet",
"Medium": "Quartz",
"Blank correction": "Not blank corrected",
"Humidity/temperature control": "None",
"Humidity/temperature control description": "filter kept at ambient conditions together with sampling head.",
"Volume std. temperature": "273.15 K",
"Volume std. pressure": "1013.25 hPa",
"Detection limit": "0.3 ug/m3",
"Detection limit expl.": "Determined by taking 3 times standard deviation of real sample low concentration",
"Measurement uncertainty": "12.0 %",
"Measurement uncertainty expl.": "includes uncertainties of the balance, volume flow measurement, paralel sampling",
"Zero/negative values": "All values below the LOD are reported as half of the LOD and then marked with a flag 781.",
"Organization": "SI01L, Hydrometeorological Institute of Slovenia, , , \"Vojkova 1/B, 61000 LJUBLJANA, Slovenia\", , , , ",
"Framework acronym": "EMEP",
"Framework name": "European Monitoring and Evaluation Programme",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Kranjc, Irena, irena.kranjc@gov.si, Slovenian Environment Agency, , Chemical Analytical Laboratory, p.p. 2608, Vojkova 1b, 1000, Ljubljana, Slovenia",
"Submitter": "Murovec, Marijana, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator."
}
|