citation |
- title:
- Ground based in situ observations of sulphur_dioxide at Iskrba (SI0008R) using uv_fluoresc
- dates:
- fileIdentifier:
- EBAS/SI0008R.20180101000000.20200306080000.uv_fluoresc.sulphur_dioxide.air.2y.1h.SI01L_ARSO_SO2_air_monitor_1.SI01L_uv_fluoresc.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "SI0008R.20180101000000.20200306080000.uv_fluoresc.sulphur_dioxide.air.2y.1h.SI01L_ARSO_SO2_air_monitor_1.SI01L_uv_fluoresc.lev2.nc",
"File creation": "20201112215922",
"Startdate": "20180101000000",
"Revision date": "20200306080000",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "2y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "SI0008R",
"Platform code": "SI0008S",
"Station name": "Iskrba",
"Station latitude": "45.566667",
"Station longitude": "14.866667",
"Station altitude": "520.0 m",
"Measurement altitude": "525.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Component": "sulphur_dioxide",
"Matrix": "air",
"Laboratory code": "SI01L",
"Instrument type": "uv_fluoresc",
"Instrument name": "ARSO_SO2_air_monitor_1",
"Instrument manufacturer": "Teledyne",
"Instrument serial number": "71",
"Method ref": "SI01L_uv_fluoresc",
"Inlet type": "Open conductive tubing",
"Inlet description": "Air inlet to instrument through teflone tube, connected to major glass inlet tube, mounted on the roof of object",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "6.35 mm",
"Inlet tube inner diameter": "4.0 mm",
"Inlet tube length": "2.0 m",
"Maintenance description": "Flow check every 3 month, inlet filter replaced every 2 months, ozone scrubber checked and replaced if needed once/year",
"Flow rate": "0.65 l/min",
"Zero/span check type": "automatic",
"Zero/span check interval": "1d",
"Humidity/temperature control": "Temperature conditioning at 20 deg. C",
"Humidity/temperature control description": "<Airconditioning of room>",
"Detection limit expl.": "Determined by instrument counting statistics, results under LOD flaged 781, results betwen LOD and LOQ flaged 780.",
"Organization": "SI01L, Hydrometeorological Institute of Slovenia, , , \"Vojkova 1/B, 61000 LJUBLJANA, Slovenia\", , , , ",
"Framework contact name": "Kjetil Tørseth, Kjetil Tørseth",
"Framework contact email": "kt@nilu.no, kt@nilu.no",
"Originator": "Gjerek, Mateja, , , , , , , , , ",
"Submitter": "Murovec, Marijana, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|