citation |
- title:
- Ground based in situ observations of nitrogen_dioxide at Iskrba (SI0008R) using CAPS
- dates:
- fileIdentifier:
- EBAS/SI0008R.20180101000000.20200914090258.CAPS.nitrogen_dioxide.air.1y.1h.SI01L_ARSO_NO2_air_monitor_1.SI01L_epa_caps.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "SI0008R.20180101000000.20200914090258.CAPS.nitrogen_dioxide.air.1y.1h.SI01L_ARSO_NO2_air_monitor_1.SI01L_epa_caps.lev2.nc",
"File creation": "20201112215908",
"Startdate": "20180101000000",
"Revision date": "20200914090258",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "1y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "SI0008R",
"Platform code": "SI0008S",
"Station name": "Iskrba",
"Station latitude": "45.566667",
"Station longitude": "14.866667",
"Station altitude": "520.0 m",
"Measurement altitude": "525.0 m",
"Measurement height": "5.0 m",
"Regime": "IMG",
"Component": "nitrogen_dioxide",
"Matrix": "air",
"Laboratory code": "SI01L",
"Instrument type": "CAPS",
"Instrument name": "ARSO_NO2_air_monitor_1",
"Instrument manufacturer": "Teledyne",
"Instrument model": "T500U",
"Instrument serial number": "71",
"Method ref": "SI01L_epa_caps",
"Inlet type": "Open conductive tubing",
"Inlet description": "Air inlet to instrument through teflone tube, connected to major glass inlet tube, mounted on the roof of object",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "6.35 mm",
"Inlet tube length": "4.0 m",
"Maintenance description": "Flow check every 3 month, inlet filter replaced every 2 months, ozone scrubber checked and replaced if needed once/year",
"Flow rate": "0.9 l/min",
"Zero/span check type": "automatic",
"Zero/span check interval": "1d",
"Humidity/temperature control": "Temperature conditioning at 20 deg. C",
"Humidity/temperature control description": "<Airconditioning of room>",
"Detection limit expl.": "Determined by instrument counting statistics, results under LOD flaged 781, results betwen LOD and LOQ flaged 780.",
"Organization": "SI01L, Hydrometeorological Institute of Slovenia, , , \"Vojkova 1/B, 61000 LJUBLJANA, Slovenia\", , , , ",
"Framework acronym": "EMEP, GAW-WDCRG",
"Framework name": "European Monitoring and Evaluation Programme, World Data Centre for Reactive Gases",
"Framework description": "The European Monitoring and Evaluation Programme (EMEP) is a scientifically based and policy driven programme under the Convention on Long-range Transboundary Air Pollution (CLRTAP) for int'l co-operation to solve transboundary air pollution problems., The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth, Kjetil Tørseth",
"Framework contact email": "kt@nilu.no, kt@nilu.no",
"Originator": "Gjerek, Mateja, , , , , , , , , ",
"Submitter": "Murovec, Marijana, , , , , , , , , ",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|