citation |
- title:
- Ground based in situ observations of ozone at Pha Din (VN0001R) using uv_abs
- dates:
- fileIdentifier:
- EBAS/VN0001R.20140101000000.20201102112326.uv_abs.ozone.air.6y.1h.VN02L_TEI49i_no120551879.VN02L_uv_abs.lev2.nc
(CodeSpace: )
- citedResponsibleParty:
- see section contact (role: distributor)
- presentationForm:
- otherCitationDetails:
- {
"Data definition": "EBAS_1.1",
"Set type code": "TU",
"Timezone": "UTC",
"File name": "VN0001R.20140101000000.20201102112326.uv_abs.ozone.air.6y.1h.VN02L_TEI49i_no120551879.VN02L_uv_abs.lev2.nc",
"File creation": "20201102193325",
"Startdate": "20140101000000",
"Revision date": "20201102112326",
"Version": "1",
"Version description": "initial revision, manually inspected",
"Data level": "2",
"Period code": "6y",
"Resolution code": "1h",
"Sample duration": "1h",
"Orig. time res.": "1mn",
"Station code": "VN0001R",
"Platform code": "VN0001S",
"Station name": "Pha Din",
"Station WDCA-ID": "GAWAID__PDI",
"Station GAW-ID": "PDI",
"Station GAW-Name": "Pha Din",
"Station land use": "Forest",
"Station setting": "Mountain",
"Station GAW type": "R",
"Station WMO region": "2",
"Station latitude": "21.5731",
"Station longitude": "103.5157",
"Station altitude": "1466.0 m",
"Measurement altitude": "1478.0 m",
"Measurement height": "12.0 m",
"Regime": "IMG",
"Component": "ozone",
"Matrix": "air",
"Laboratory code": "VN02L",
"Instrument type": "uv_abs",
"Instrument name": "TEI49i_no120551879",
"Instrument manufacturer": "Thermo",
"Instrument model": "49i",
"Instrument serial number": "no120551879",
"Method ref": "VN02L_uv_abs",
"Standard method": "SOP=GAW_209(2013)",
"Inlet type": "Hat or hood",
"Inlet description": "inlet approx. 6 m above the building and 12 m above the ground; coarse mesh at the top of the inlet to protect against spiders etc.; 47 mm teflon filter (5 micron) just upstream of the instrument inlet.",
"Inlet tube material": "Teflon",
"Inlet tube outer diameter": "6.35 mm",
"Inlet tube length": "15.0 m",
"Maintenance description": "inlet filter (47 mm teflon filter (5 micron)) changed every 2 months. Coarse filter is visually inspected twice a year. Zero and span checks are irregularly performed with an external zero air unit and the internal ozonator.",
"Flow rate": "0.5 l/min",
"Zero/span check type": "manual",
"Humidity/temperature control": "None",
"Absorption cross section": "1.1476e-17 cm2",
"Organization": "VN02L, National Hydro-Meteorological Service, NMHS, , \"No. 3 Dang Thai Than street,100000 Hanoi,Vietnam\", , , , ",
"Framework acronym": "GAW-WDCRG",
"Framework name": "World Data Centre for Reactive Gases",
"Framework description": "The World Data Centre for Reactive Gases is the data repository and archive for reactive gases of the World Meteorological Organisation's (WMO) Global Atmosphere Watch (GAW) programme.",
"Framework contact name": "Kjetil Tørseth",
"Framework contact email": "kt@nilu.no",
"Originator": "Nguyen, Nhat Anh, anhnnhn@gmail.com, Hydro-Meteorological and Environmental Station Network Center, HYMENET, , 62 Nguyen Chi Thanh Str., , , Hanoi, Viet Nam",
"Submitter": "Steinbacher, Martin, martin.steinbacher@empa.ch, Swiss Federal Laboratories for Materials Science and Technology, Empa, Air Pollution/Environmental Technology, Ueberlandstrasse 129, , CH-8600, Duebendorf, Switzerland",
"Acknowledgement": "Request acknowledgement details from data originator"
}
|